    ±öÌï³å°æ»úABBËÅ·þÇý¶¯Æ÷άÐÞ-MotiFlex e180±¨¾¯4018άÐÞ

    ·¢²¼ÕߣºZY    À´Ô´£ºÉϺ£³¤Õ÷ÓéÀÖ     ·¢²¼Ê±¼ä£º2023-2-1

    ±öÌï³å°æ»úABBËÅ·þÇý¶¯Æ÷άÐÞ-MotiFlex e180±¨¾¯4018άÐÞ

      ABB MotiFlex e180ËÅ·þÇý¶¯Æ÷±¨¾¯4018άÐÞ
    4018 Can't fit model to voltagelcurrent data (_eaCANNOT_FIT_RESISTANCE_MODEL)
    4018²»ÄÜÄâºÏµçѹµçÁ÷Êý¾Ý(_eaCANNOT_FIT_FIT_µç×èÄ£ÐÍ)
    During the Measure motor resistance and inductance test, a gradually increasing voltage is applied to the motor and the
    ÔÚ²âÁ¿µç»úµç×èºÍµç¸ÐµÄÊÔÑéÖУ¬¶Ôµç»úÊ©¼ÓÒ»¸öÖð½¥Ôö¼ÓµÄµçѹ¡£
    generated current is logged.The process is stopped when the drive current reaches 80% of the specifed motor rated currentvalue.The resulting voltage/current characteristic is used to calculate the resistance of the windings and certain parameters ofthe drive's power stage.Error 4018 will occur if there is not enough data in the voltage/current characteristic to perform thecalculation.
    µ±Çý¶¯µçÁ÷´ïµ½Ö¸¶¨µç»ú¶î¶¨µçÁ÷ÖµµÄ80%ʱ£¬¸Ã¹ý³ÌÍ£Ö¹¡£Óɴ˲úÉúµÄµçѹ/µçÁ÷ÌØÐÔÓÃÓÚ¼ÆËãÈÆ×éµÄµç×èºÍÇý¶¯Æ÷¹¦Âʼ¶µÄijЩ²ÎÊý¡£Èç¹ûµçѹ/µçÁ÷ÌØÐÔÖÐûÓÐ×ã¹»µÄÊý¾ÝÀ´½øÐмÆË㣬Ôò»á³öÏÖ´íÎó4018¡£
    The error can also occur because of a motor or wiring fault. Check that the motor is wired correctly and there are no short-circuits.ldeally, remove AC power from the drive, unplug the motor power connector (X1), and use a test meter to check theresistance across the UN, VW and WlU terminals of the cable connector. The three resistance values should be the same andmatch the catalog values specified for the motor.
    ¸Ã´íÎóÒ²¿ÉÄÜÒòΪµç»ú»òÏß·¹ÊÕ϶ø·¢Éú¡£¼ì²éµç»ú½ÓÏßÕýÈ·£¬Ã»ÓжÌ·¡£Ê×ÏÈ£¬´ÓÇý¶¯Æ÷ÖÐÈ¡³ö½»Á÷µçÔ´£¬°Î³öµç»úµçÔ´Á¬½ÓÆ÷(X1)£¬²¢Ê¹ÓòâÊÔ±í¼ì²éµçÀÂÁ¬½ÓÆ÷µÄUN¡¢VWºÍWLU¶Ë×ӵĵç×è¡£ÕâÈý¸öµç×èÖµÓ¦¸ÃÊÇÏàͬµÄ£¬²¢Æ¥ÅäΪµç»úÖ¸¶¨µÄĿ¼ֵ¡£
    Occasionally, error 4018 will ccur if the motor rated current specified in the Drive Setup Wizard is particularly low for the size ofmotor. Provided that the value has been set up correctly, you will need to avoid the Measure motor resistance and inductancetest. To do this, manually enter the motor resistance and inductance in the Confrm Motor Information page of the Drive SetupWizard (most motor manufacturers will supply this information) and confrm that the test is not selected in the Autotune tool.Once autotuning is complete, check that the response of the current controllers is satisfactory using the Fine-tuning tool'sCurrent tab.
    ż¶û£¬Èç¹ûÇý¶¯Æ÷°²×°Ïòµ¼ÖÐÖ¸¶¨µÄµç»ú¶î¶¨µçÁ÷¶ÔÓÚµç»úµÄ´óСÀ´ËµÌرðµÍ£¬Ôò´íÎó4018½«µ¼ÖÂCCUR¡£Ö»ÒªÖµÉèÖÃÕýÈ·£¬¾ÍÐèÒª±ÜÃâ²âÁ¿µç»úµç×èºÍµç¸Ð¡£Îª´Ë£¬ÇëÔÚÇý¶¯Æ÷SetupWizardµÄConfrmµç»úÐÅÏ¢Ò³ÃæÖÐÊÖ¶¯ÊäÈëµç»úµç×èºÍµç¸Ð(´ó¶àÊýµç»úÖÆÔìÉ̽«Ìṩ´ËÐÅÏ¢)£¬²¢È·ÈϲâÊÔδÔÚ×Ô¶¯Í¼ÌÚ¹¤¾ßÖÐÑ¡Ôñ¡£Ò»µ©Íê³É×Ô¶¯Õû¶¨£¬ÇëʹÓÃ΢µ÷¹¤¾ßµÄCurrentÑ¡Ï¼ì²éµ±Ç°¿ØÖÆÆ÷µÄÏìÓ¦ÊÇ·ñÁîÈËÂúÒâ¡£
      ±öÌï³å°æ»úabbËÅ·þÇý¶¯Æ÷άÐÞ¹ÊÕÏ£ºÍ¨µç±¨¾¯¡¢MotiFlex e180¹ýÔØ¡¢¹ýѹ¡¢¹ýÁ÷¡¢²»ÄÜÆô¶¯¡¢Æô¶¯ÎÞÁ¦¡¢ÔËÐж¶¶¯¡¢Ê§´Å¡¢¹ýÁ÷¡¢¹ýÔØ¡¢ÅÜλ¡¢Êä³ö²»Æ½ºâ¡¢±àÂëÆ÷±¨¾¯¡¢±àÂëÆ÷Ë𻵡¢Î»Öò»×¼ һͨµç¾Í±¨¾¯ һͨµç¾ÍÌøÕ¢ ´ÅÌú±¬¸Ö¿¨ËÀת²»¶¯ ±àÂëÆ÷Ä¥Ëð µç»ú·¢ÈÈ·¢ÌÌάÐÞ µç»úÔËתÒì³£¡¢¸ßËÙÔËתÔëÒô´ó»¹ÓÐɲ³µÊ§ÁéάÐ޵ȸ÷ÖÖ¹ÊÕÏ£¬²»ÓÚabbËÅ·þÇý¶¯Æ÷£¬Í¬Ê±Ò²°üÀ¨ÆäËü¸÷ÖÖÆ·ÅƵÄËÅÇý¶¯Æ÷¡£


    ×ªÔØÇë×¢Ã÷³ö´¦£ºÉϺ£³¤Õ÷ÓéÀֿƼ¼×¨ÒµËÅ·þÇý¶¯Æ÷άÐÞ,ËÅ·þµç»úάÐÞ
    ±¾ÎÄÁ´½Ó£º/fuwu/Services_Show13681.htm
    ËÅ·þÇý¶¯Æ÷άÐÞ ËÅ·þµç»úάÐÞ  ´¥ÃþÆÁάÐÞ   ±äƵÆ÷άÐÞ


    ÁªÏµ·½Ê½£º

    µç»°£º021-50157782
    ÊÖ»ú£º13817011982 ΢ÐÅͬºÅ
    ÓÊÏ䣺shygdzi@163.com
    ÁªÏµÈË£ºÕʤ
    꿅᣼
    ¡¾ ÎÒÃÇÈ·±£Ð޺òâÊԺøø¿Í»§£¡£¡£¡£¡¡¿

    ÉÏһƪ£º¹ã¶«¿â¿¨»úÆ÷ÈËËÅ·þµç»ú1FK7100-5AZ91-1ZZ9-ZάÐÞÖÐÐÄ
    ÏÂһƪ£ºÉعØÎ÷ÃÅ×Ó¹¤¿Ø»úIPC3000¿ª»úʱ´ò²»¿ª£¬³öÏÖÒ»´®Ó¢ÎÄ×Öĸ¹ÊÕÏÄÄÀïÐÞ

    ×îÐÂÏà¹ØÄÚÈÝÍÆ¼ö£º
     
    ¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿